Optical Channel Monitoring Card(OCM) are used for DCI BOX
The main function of the Optical Channel Monitor board (OCM) is to analyze the transmission signal performance of DWDM system in the wavelength range of 1528nm-1567nm, such as co-wave signal spectrum, channel optical power, wavelength and other transmission signals. It has the characteristics of high stability, high sensitivity, accuracy, high dynamic range and short scanning time. It is an indispensable part in the optical performance monitoring of DWDM system.
Datasheet Optical channel monitoring board(OCM) Function The center wavelength, optical power and other parameters of each channel in the involutory wave optical signal are tested Ports Provides 8 test interfaces (selected by optical switch), which can access the 8-core circuit optical signal test Operating wavelength range 1528.57 nm ~1567.34 nm (191.27THz~196.15THz) Channel spacing 50/100 GHz,Flexible Grid support Center wavelength detection accuracy ±0.1 nm Center wavelength resolution 0.02 nm Channel power monitoring range -40 ~ -10 dBm Power absolute accuracy ≤1 dB Power relative accuracy ±0.8 dB Optical power resolution 0.1 dB Return loss ≥40dB Scanning time ≤1 s Number of scans >(10)^9
Application Suitable for end-to-end monitoring of optical performance. Suitable for DCI Box.